Industrial equipment
maintenance, repair
and commissioning
Diagnostic and repair at our own
service centers
9 Siemens service technicians and
more than 60 specialists employed
Original parts and equipment
in stock and available to order
 
We ensure
uninterrupted
operation of your
equipment, reducing
downtime and expenses
We offer consultations, perform repairs,
and handle equipment commissioning
We do maintenance of electrical
equipment
We supply a wide range of industrial
equipment from Siemens and other vendors
We evaluate the condition
of mechanical equipment and provide
vibration monitoring
We provide comprehensive maintenance
for production facilities: mechanical,
electrical, and hydraulic equipment
We do maintenance and commissioning
of medium voltage frequency converters
and soft starters
Simovert Masterdrive VC и MC
Micromaster 410, 420, 430, 440
Simodrive 611U, 611D,
Sinamics V20, V70, V90, G120, G120C,
G120X, G120P
Simoreg DC Master
Sinamics DCM
Sinamics G130, G150, S150, GM150, SM150
Loher Dynavert T, Sinamics G180
Sinamics GH180 / Perfect Harmony / ASIRobicon
Sirius soft starter 3RW
Sinumerik 802D, 802DSL, 810D, 840DI, 840DPL,
840DSL, 808D, 828D
Simotion D
HMI and Sinumerik OP control panels
Sitop power supplies
Sinumerik PCU50
Control panels
Altivar Schneider Electric
Solcon soft startes
ACS ABB
Motors: 1FK, 1FT, 1PH8
General induction motors from
any manufacturer
Controllers: S7-300, S7-400, S7-1200, S7-1500
If your equipment is not on the list, send
us a message or feel free to call us at
8 (800) 777-83-86
Equipment that
we service
Free of charge equipment
diagnostic
We'll diagnose your
equipment for free if you choosing
repair from us
Or call us at 8 (800) 777-83-86
to consult an expert
Diagnostic is performed at one of our service
centers in Moscow, Saint Petersburg
or Lipetsk, or by a service engineer
at your facility
 
How we work
Consultation
We analyze your inquiry, ask
questions for additional clarification,
and compile a list of possible causes
We provide diagnostic of your
equipment at our service center or
send a technician to your facility
Diagnostic
We sign a contract and perform
the repairs using original parts
Repair
We test equipment performance
and perform commissioning
if necessary
Testing
You accept our work, pay the
balance due, and put the
equipment into operation
Start-up
Experience: 15 years
employedChief engineer for equipment installation and repair
Specialization:
Repair and maintenance
of variable frequency drives
Experience: 17 years
employedChief engineer for equipment installation and repair
Specialization:
repair and maintenance
of servomotors and Sinumerik
CNC systems
Experience: 8 years
employedChief engineer for equipment installation and repair
Specialization:
Repair and maintenance
of frequency converters
employedChief engineer for equipment installation and repair
Experience: 17 years
Specialization:
Repair and maintenance
of variable frequency drives
employedChief engineer for equipment installation and repair
Experience: 10 years
Specialization:
PLC programming, sensors
systems maintenance, production
line modernization
employedChief engineer for equipment installation and repair
Experience: 8 years
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
employedChief engineer for equipment installation and repair
Experience: 20 years
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
employedChief engineer for equipment installation and repair
Experience: 17 years
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
employedChief engineer for equipment installation and repair
Experience: 23 years
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
Back
Next
9 service engineers from
Siemens employed
Construction
Cement
Metallurgical
Food
Glass
Extraction
Wood processing
Petroleum
Paper
Metal processing
We ensure uninterrupted equipment
operation
We reduce costs and increase
production efficiency
We increase process line productivity
and reliability
We implement energy-saving technologies
We work with
companies
from various
industries
Check out these projects
that our engineers have
completed
Equipment: Sinamics Powerblock
6SL3352-1AG41-0FA1 – 2 pcs
Industry: Timber processing
Declared issue: While operating the equipment,
error F30022 occurred ("Power unit: control Uce")
Solution: Diagnostic of the power part of the units
found an electrical breakdown in one of the power
transistor modules, allowing high voltage into
the command circuit of a power tong door. The repair
involved replacing 2 transistor
modules and control boards for IGD5/R2 power tongs
at each block. Decontamination was performed.
Upon completion of remedial actions, the power blocks
successfully passed a function test using special testing
equipment.
Client: A major supplier in the oilfield
services industry
Equipment: Sinamics Powerblock
6SL3353-1AE35-3DA1
Declared issue: An error in the IGBT control
of the electronic map of the power module
Client: A major distributor of drive equipment
and integrated solutions
Equipment: Direct current converter
Simoreg DCM 6RA7025-6DV62-0-Z S00
Declared issue: Returned by end
customer; no defect specified
Solution: Troubleshooting of the converter found
a hardware defect in the diode transistor module,
which triggered the errors specified when bringing
the converter online to the motor. In the course of
the repairs this module was replaced.
Decontamination was performed. Upon completion
of remedial actions, the converter was successfully
tested in operation with the motor in standard
operating mode.
Declared issue: A 2310 output overcurrent
error and a 3181 motor cable carrier connection error
Equipment: General purpose frequency converter
ABB ACS580-01-017A-4
Industry: A major parts supplier in the
field of automation and assembly of
specialized cabinets
Equipment: Simatic Touch Panel OP177B PN/DP T/K-6
CSTN 6AV6642-0DA01-1AX1 image panel
Solution: Diagnostic of the panel found a hardware
defect in the display backlight circuit.
In the course of the repairs the display panel was
replaced. Decontamination was performed. Following
remedial actions, the panel was successfully tested
in normal operating mode.
Declared issue: The panel "went dark"
Industry: Paper-making
Back
Next
Back
Next
Certificates and licenses
Get a consultation
from an engineer
 
Service centers:
Moscow
Saint Petersburg
Lipetsk
Moscow, Zelenyy Prospekt 5/12, bldg. 2
Сайт разработан в веб-студии ONE PAGE
Privacy Policy
© Union Industrials LLC, 2012–2022