More than 10 years of experience in industrial
equipment supply and service
8 (800) 777-83-86
Diagnostic and
repair at our own
service centers
9 Siemens service
technicians and more
than 60 specialists employed
Original parts and
equipment in stock
and available to order
 
Industrial equipment
maintenance, repair
and commissioning
Response time of 1 hour or less;
prompt on-site visit by technician

ТО, ремонт и пусконаладка
промышленного оборудования

We offer consultations, perform repairs,
and handle equipment commissioning
We do maintenance of electrical
equipment
We ensure uninterrupted operation of your
equipment, reducing downtime and expenses
We supply a wide range of industrial equipment
from Siemens and other vendors
We provide comprehensive maintenance for production
facilities: mechanical, electrical, and hydraulic equipment
We do maintenance and commissioning of medium
voltage frequency converters and soft starters
We evaluate the condition of mechanical
equipment and provide vibration monitoring
Equipment that we service
Simovert Masterdrive VC и MC
Micromaster 410, 420, 430, 440
Simodrive 611U, 611D,
Sinamics V20, V70, V90, G120, G120C,
G120X, G120P
Simoreg DC Master
Sinamics DCM
Sinamics G130, G150, S150, GM150, SM150
Loher Dynavert T, Sinamics G180
Sinamics GH180 / Perfect Harmony / ASIRobicon
Sirius soft starter 3RW
Sinumerik 802D, 802DSL, 810D, 840DI, 840DPL,
840DSL, 808D, 828D
Simotion D
HMI and Sinumerik OP control panels
Sitop power supplies
Sinumerik PCU50
Control panels
Altivar Schneider Electric
Solcon soft startes
ACS ABB
Motors: 1FK, 1FT, 1PH8
General induction motors from
any manufacturer
Controllers: S7-300, S7-400, S7-1200, S7-1500
If your equipment is not on the list, send us a message
or feel free to call us at 8 (800) 777-83-86
 
Free of charge equipment diagnostic
We'll diagnose your equipment for free
if you choosing repair from us
Or call us at 8 (800) 777-83-86 to consult an expert
Consultation
How
we work
We analyze your inquiry, ask
questions for additional clarification,
and compile a list of possible causes
Diagnostic
We provide diagnostic of your
equipment at our service center or
send a technician to your facility
Testing
We test equipment performance
and perform commissioning
if necessary
Start-up
You accept our work, pay the
balance due, and put the
equipment into operation
We sign a contract and perform
the repairs using original parts
Repair
Experience: 15 years
9 service engineers from Siemens employed
Chief engineer for equipment
installation and repair
Specialization:
Repair and maintenance
of variable frequency drives
Experience: 17 years
Chief engineer for equipment
installation and repair
Specialization:
repair and maintenance
of servomotors and Sinumerik
CNC systems
Experience: 8 years
Chief engineer for equipment
installation and repair
Specialization:
Repair and maintenance
of frequency converters
Experience: 17 years
Chief engineer for equipment
installation and repair
Specialization:
Repair and maintenance
of variable frequency drives
Experience: 10 years
Chief engineer for equipment
installation and repair
Specialization:
PLC programming, sensors
systems maintenance, production
line modernization
Experience: 8 years
Chief engineer for equipment
installation and repair
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
Experience: 20 years
Chief engineer for equipment
installation and repair
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
Experience: 17 years
Chief engineer for equipment
installation and repair
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
Experience: 23 years
Chief engineer for equipment
installation and repair
Specialization:
Repair and maintenance
of variable frequency drives,
production line modernization
Construction
We work with companies
from various industries
Cement
Metallurgical
Food
Glass
Extraction
Wood processing
Petroleum
Paper
Metal processing
We ensure uninterrupted equipment operation
We reduce costs and increase production
efficiency
We increase process line productivity
and reliability
We implement energy-saving technologies
Check out these projects that our
engineers have completed
Equipment: Sinamics Powerblock
6SL3352-1AG41-0FA1 – 2 pcs
Industry: Timber processing
Declared issue: While operating the equipment,
error F30022 occurred ("Power unit: control Uce")
Solution: Diagnostic of the power part of the units
found an electrical breakdown in one of the power
transistor modules, allowing high voltage into
the command circuit of a power tong door. The repair
involved replacing 2 transistor
modules and control boards for IGD5/R2 power tongs
at each block. Decontamination was performed.
Upon completion of remedial actions, the power blocks
successfully passed a function test using special testing
equipment.
Client: A major supplier in the oilfield
services industry
Equipment: Sinamics Powerblock
6SL3353-1AE35-3DA1
Declared issue: An error in the IGBT control
of the electronic map of the power module
Client: A major distributor of drive equipment
and integrated solutions
Equipment: Direct current converter
Simoreg DCM 6RA7025-6DV62-0-Z S00
Declared issue: Returned by end
customer; no defect specified
Industry: A major parts supplier in the field of automation
and assembly of specialized cabinets
Equipment: General purpose frequency converter
ABB ACS580-01-017A-4
Declared issue: A 2310 output overcurrent
error and a 3181 motor cable carrier connection error
Solution: Troubleshooting of the converter found a hardware
defect in the diode transistor module, which triggered the
errors specified when bringing the converter online to the motor.
In the course of the repairs this module was replaced.
Decontamination was performed. Upon completion of remedial
actions, the converter was successfully tested in operation
with the motor in standard operating mode.
Industry: Paper-making
Equipment: Simatic Touch Panel OP177B PN/DP T/K-6 CSTN 6AV6642-0DA01-1AX1 image panel
Declared issue: The panel "went dark"
Solution: Diagnostic of the panel found a hardware defect in the display backlight circuit.
In the course of the repairs the display panel was replaced. Decontamination was performed. Following remedial actions, the panel was successfully tested in normal operating mode.
Back
Next
Certificates and licenses
Back
Next
Get a consultation
from an engineer
 
8 (800) 777-83-86     mail@industry-services.ru
Service centers:
Moscow
Saint Petersburg
Lipetsk
Moscow, Zelenyy Prospekt 5/12, bldg. 2
Сайт разработан в веб-студии ONE PAGE
Privacy Policy
© Union Industrials LLC, 2012–2022